AcousticX™
High-speed LED array light source for real-time photoacoustic imaging
Developed by CYBERDYNE, Inc.. Distributed in North America by Amuza Inc.
AcousticX™ is an LED-based photoacoustic and ultrasound imaging system that visualizes blood vessels and oxygenation in real time. By combining optical absorption with ultrasound, the system displays capillary vessels and oxygen saturation differences that are difficult to capture with ultrasound alone.
Features

3D fingertip capillary imaging (photoacoustics)
AcousticX acquires photoacoustic and ultrasound information simultaneously and displays it on the system monitor. This combined methodology reveals structures and functional contrast, such as capillary networks and oxygenation, that are hard to visualize otherwise.
LED Array Light Source
To address the cost and power requirements of conventional laser-based photoacoustic systems, AcousticX adopts a high-power LED array light source.
Benefits include:
No laser-safe room or protective goggles required
Lower energy consumption and cost of ownership
Compact, accessible setup for research environments

Video

CYBERDYNE AcousticX Promotion (2020)
3D imaging of capillary vessels
Real-time imaging: occluding and releasing fingertip blood flow
AcousticX Webinars

LED-based Photoacoustic Molecular Imaging

Tomographic imaging with an LED-based photoacoustic and ultrasound system

LED-based photoacoustic imaging for detection and staging of inflammatory arthritis

Studies of precision and accuracy in LED-based photoacoustics

Guidance of minimally invasive peripheral vascular access procedures using LED-based photoacoustic imaging

LED-based photoacoustic imaging system for preclinical cancer research
— Dr. Srivalleesha Mallidi

Photoacoustic Imaging Capabilities of Light-Emitting-Diode (LED) Arrays
— Dr. Sri-Rajasekhar Kothapalli
Featured Publications
Technical validation studies of a dual-wavelength LED-based photoacoustic and ultrasound imaging system
James Joseph, Mithun Kuniyil Ajith Singh, Naoto Sato, Sarah Bohndiek
Summary
Technical and biological validation of AcousticX (LED-based PA + US)
Dual-wavelength capability shows excellent repeatability, reproducibility, and precision (phantoms)
Small-animal imaging demonstrates mapping of blood oxygenation and exogenous contrast uptake in real time
Supports AcousticX as a promising alternative to bulky, expensive laser-based systems for functional and molecular imaging
LED-based Photoacoustic Imaging: From Bench to Bedside (Book)
Mithun Kuniyil Ajith Singh (Editor)
Summary
First book on LED-based photoacoustic imaging
Covers fundamentals, instrumentation, reconstruction, and image processing
Preclinical and clinical applications, with contributions from academia and industry
Opportunities and challenges for clinical translation
Towards Clinical Translation of LED-Based Photoacoustic Imaging: A Review
Yunhao Zhu, Ting Feng, Qian Cheng, Xueding Wang, Sidan Du, Naoto Sato, Jie Yuan, Mithun K. A. Singh
Summary
First comprehensive scientific review on LED-based PA imaging
Historical development and latest advances
Comparison of illumination sources (lasers, laser diodes, LEDs) in cost, portability, specifications
Summarizes preclinical and clinical applications up to early 2020
Detecting joint inflammation by an LED-based photoacoustic imaging system: a feasibility study
Junggun Jo, Guan Xu, Yunhao Zhu, Mary Burton, Jeffrey Sarazin, Elena Schiopu, Girish Gandikota, Xueding Wang
Summary
First clinical pilot showing LED-PA utility in inflammatory arthritis
Compared LED-PA images across active, subclinical, and normal joints vs. Doppler US
LED-PA showed higher sensitivity for angiogenic microvasculature
Indicates potential for portable, non-invasive detection and monitoring
Molecular imaging of oxidative stress using an LED-based photoacoustic imaging system
Ali Hariri, Eric Zhao, A. S. Jeevarathinam, Jeanne Lemaster, Jianjian Zhang, Jesse V. Jokerst
Summary
First preclinical demonstration of molecular imaging with LED-based PA
Measured RONS using CyBA and LED-PA; no photobleaching vs. laser systems
Confirms potential of LED-PA for sensitive molecular applications with reduced size and cost
Tomographic imaging with an ultrasound and LED-based photoacoustic system
K. J. Francis, Y. E. Boink, M. Dantuma, M. K. A. Singh, S. Manohar, W. Steenbergen
Summary
Method for tomographic US + LED-PA imaging
Multiple illumination configurations for human finger and animal brain
High-resolution images support applications in arthritis diagnosis and treatment monitoring, especially in resource-limited settings
Handheld real-time LED-based PA + US system for needle and superficial vasculature guidance
W. Xia, M. K. A. Singh, E. Maneas, N. Sato, Y. Shigeta, T. Agano, S. Ourselin, S. J. West, A. E. Desjardins
Summary
Demonstrates guidance of minimally invasive procedures with LED-PA
Higher contrast of needle shaft and tip vs. US alone
Phantom and volunteer studies indicate potential for surgical guidance in portable, resource-limited settings
Diagnosis and Treatment Monitoring of Port-Wine Stain Using LED-Based Photoacoustics
Qian Cheng, Menglu Qian, Xiuli Wang, et al.
Summary
First pilot for PWS diagnosis and treatment monitoring with LED-PA
22 patients; comparisons with dermoscopy (gold standard)
Introduces a new LED-PA index for detection and PDT monitoring
Shows LED-PA as a valuable tool for early diagnosis and therapy guidance
| Specification | Details |
|---|---|
| Maximum Depth | 40 mm |
| Light Source | High-density, high-power LED Wavelengths (single): 690, 750, 820, 850, 940 nm Combinations (dual): 690/850, 750/850, 820/940 nm Repetition rate (PRF): 1, 2, 3, or 4 kHz Pulse width: 30–150 ns (selectable) |
| Driver Ports | 4 |
| Transducer | 7 MHz or 10 MHz linear array |
| PA Processing Channels | 128-channel parallel receiving |
| Scan Modes | Photoacoustic 2D; Ultrasound 2D |
| External Trigger Output | For pulsed laser systems |
| Power | AC 100–240 V |
| Monitor | Color LCD |
| Software Options | 3D imaging package (integrated automatic stage), oxygenation package, high-speed photoacoustic package, raw data access |
| Environment | No protective goggles required; no laser classification required |
| *Figures may vary depending on options and settings. | |
Learn More / Contact Us
Developed by CYBERDYNE, Inc.. Distributed and supported in North America by Amuza Inc.
For demos, quotes, or configuration guidance
Regulatory notice: Research Use Only. Not for diagnostic use.