HPLC-ECD Component System, 800 Series

(Formerly the 700 Series)

Protect your electrochemical data from noise, drift, and system limitations

Electrochemical detection offers unmatched sensitivity for electroactive compounds — but it also exposes weaknesses in conventional HPLC setups. Flow pulsation, temperature instability, and incompatible materials can quietly degrade signal quality, reduce reproducibility, and put critical data at risk.

The Eicom HPLC-ECD Component System, 800 Series is designed to address these risks directly, giving researchers a stable, flexible platform for high-sensitivity electrochemical analysis.

 

The Problem: Common challenges in electrochemical detection

Many laboratories encounter these issues when using electrochemical detection with conventional HPLC systems:

  • Baseline noise and drift caused by pump pulsation

  • Reduced sensitivity when ECDs are paired with non-optimized LC systems

  • Retention time variability due to insufficient temperature control

  • Limited flexibility in systems that cannot expand as methods evolve

These challenges increase troubleshooting time, consume valuable samples, and reduce confidence in analytical results.

The Solution: A system designed to address these challenges

The HPLC-ECD Component System, 800 Series
(formerly the 700 Series) is a modular platform engineered to provide stable, high-sensitivity electrochemical analysis while integrating cleanly with existing HPLC setups.

  • ECD-800 — ultra-high sensitivity electrochemical detection

  • EP-800 — pulse-free liquid delivery with integrated degassing

  • ATC-800 — temperature control for stable retention times and signal response

Outcome: cleaner baselines, more reproducible runs, and flexibility as methods evolve.

How each component reduces risk and improves results

Electrochemical Detector, ECD-800

(Formerly ECD-700)

Risk addressed: signal noise, electrode instability, limited detection flexibility

The ECD-800 Electrochemical Detector provides ultra-high sensitivity by combining a three-electrode potentiostat design with a shielded flow cell architecture. This minimizes electrical noise and stabilizes applied potential at the working electrode.

Key benefits include:

  • High-sensitivity amperometric DC detection

  • Support for amperometric or coulometric detection modes

  • Optional dual working electrode configurations

  • Compatibility with a wide range of electrode materials, including graphite composite, glassy carbon, platinum, gold, and silver

  • Easy access to electrodes for routine maintenance

The ECD-800 allows established electrochemical methods to be transferred confidently while supporting new application development.

Pump System, EP-800

(Formerly EP-700)

Risk addressed: baseline noise caused by flow pulsation and contamination

Electrochemical detection is highly sensitive to flow instability. The EP-800 Pump System is engineered specifically to reduce pulsation at the source, eliminating one of the most common causes of ECD noise.

Key benefits include:

  • Reciprocal dual-piston pump with self-learning pulsation control

  • No external pulse damper required

  • Built-in two-channel online degasser

  • Support for one or two pumps for isocratic, gradient, or parallel workflows

  • Inert, non-metallic wetted surfaces to reduce background current

The EP-800 delivers stable, pulse-free flow for consistent electrochemical detection across a wide range of applications.

    Temperature Controller, ATC-800

    (Formerly ATC-700)

    Risk addressed: retention time drift and poor run-to-run reproducibility

    Even small temperature fluctuations can affect retention time and detector response. The ATC-800 Temperature Controller stabilizes both HPLC columns and electrochemical flow cells to maintain consistent analytical conditions.

    Key benefits include:

    • Active heating and cooling using a Peltier element

    • Precise temperature regulation for improved reproducibility

    • Capacity for two columns up to 25 cm

    • Direct integration with the ECD-800 shielding box for flow cell temperature control

    By controlling temperature at critical points in the system, the ATC-800 helps ensure reliable, repeatable results.

    A system that adapts as your research evolves

    The 800 Series is modular by design. Laboratories can:

    • Start with a single component (e.g., ECD-800 only)

    • Add pumps, detectors, or temperature control as methods expand

    • Run parallel applications or gradient workflows

    • Integrate with existing HPLC systems

    This flexibility reduces the risk of outgrowing your instrumentation and protects long-term investment.

    Typical applications

    The HPLC-ECD Component System, 800 Series is commonly used for:

    • Neurochemical and neurotransmitter analysis

    • Microdialysis (offline and online)

    • Trace electroactive compound detection

    • Method development requiring ultra-high sensitivity

    • Research workflows demanding low noise and high stability

    Specifications

    The 800 Series succeeds the proven 700 Series platform. Core performance specifications remain consistent, with updated model designations and standardized system integration.

    ECD-800

    Electrochemical CellAmperometric with 3 electrode DC potentiostat (standard); space for an optional second cell
    Second Cell (Optional)Coulometric or amperometric
    Working ElectrodeGraphite composite (standard), glassy carbon, pure graphite, platinum, gold, silver
    Optional Dual ElectrodeGlassy carbon, graphite composite (both due a shared reference)
    Reference ElectrodeAg/AgCl
    Counter Electrode316 stainless steel
    Applied Voltage Range-2000 mV to +2000 mV, 1 mV increments
    Auto Zero FunctionBetween -1000 nA and +1000 nA; triggered by external input

    EP-800 PUMP UNIT

    Pressure Limit20 MPa
    Setting Flow Rate1~3000μL/min
    Stable Flow Pump100~2000μL/min
    Liquid Contacting SurfacesPEEK, Sapphire, Ruby, PTFE, PCTFE
    Special FeaturesGradient control built-in, input signal for start/stop
    Built-in Degasser2 channels: 300 µL volume/ea, up to 3.0 mL/min

    ATC-800

    Temperature Range15-55°C, 1°C increment, 20-45°C (recommended range)
    Temperature Accuracy+/-0.05°C

    The specifications are subject to change without notice.