AtmosLM™ for In Vivo Protein and Peptide Microdialysis


Eicom Syringe Pump, ESP-32 Amuza Rotating Cage Stage (RCS-91, RCS-92) Eicom Roller pump, ERP-10 Microdialysis Fraction Collector, FC-90

Your probes have been very reliable and have opened our research to many new areas not possible before.

Prof. John Cirrito

Washington University

Pressure Canceling Microdialysis For the Recovery Of Large Molecules, Neuropeptides, Cytokines, and Proteins.

AtmosLM™ microdialysis probes feature large pore membranes for better recovery of large molecules such as antibodies, neuropeptides, and cytokines. Large molecule recovery with microdialysis has always been challenging because large pore membranes are prone to leakage (ultrafiltration) when under pressure. The Eicom AtmosLM™ Microdialysis Probes incorporate a vent hole at the head of the probe to equalize the pressure inside the membrane with outside atmospheric pressure. (Patented)

Pressure Canceling Technology Used in AtmosLM™

 

AtmosLM-pressure-canceling-technology

User Reported Detectable Molecules with in Vivo Use

  • Amyloid β1-40 (4 kDa)
  • Monoclonal antibodies
  • ApoE particles (>200 kDa)
  • IL-1 β (17 kDa)
  • IL-6 (26 kDa)
  • Tau Protein (>50 kDa)
  • TNF-α (17 kDa)
  • CRF (5 kDa)
  • α-synuclein (14 kDa)

(Contact us for detailed conditions.)

Membrane Types

Polyethylene (PE) Membrane with 1,000 kDa Cut Off, 0.44 mm outer diameter.

Variety of Sizes Available for AtmosLM™ Microdialysis Probes

Aside from the Pressure Canceling Technology, the AtmosLM™ Microdialysis Probe, model PEP, is like our AZ microdialysis probes. We carry standard sizes of 4, 8, or 12 mm for the shaft length (X mm) and 1, 2, 3, or 4 mm for the membrane length (Y mm). Other sizes are available.

System Requirements

To collect the sample from the probe, a “pull” pump is required in addition to the infusion syringe pump. Eicom has developed a new peristaltic pump, the ERP-10, specifically for the AtmosLM™ system. The ERP-10 completes the AtmosLM™ system offered by Eicom, an incredibly convenient large molecule sampling system. The tubing from the syringe pump to the PEP-probes should be 0.1 mm ID (JT-10 or WT-35). The tubing from the PEP probe to the ERP-10 should be 0.25 mm ID (JF-10 or WT-35). The WT-35 has two tubes covered by a protective sheath. One tube is 0.1 mm ID (inlet) and the second is 0.25 mm ID (outlet).

Microdialysis Options

The FC-90 fraction collector provides refrigerated fraction collection from up to four probes simultaneously. The samples are stored in a 96 well plate with resealing plate seals to prevent evaporation and cross-contamination of samples.

The RCS-91 rotating cage stage and balance arm obviates the need for swivels: when the animal rotates, the stage rotates in the opposite direction to eliminate twisting in the animal’s tether. The RCS-91 also obviates the need for electrical and optical slip rings, making it much easier to combine microdialysis, electrophysiology, and optogenetic equipment in the same experiment.